Heavy-Up Electrical Service & Meter Base Upgrade
Overhead mast and underground lateral infrastructure upgrades coordinated with GTA utility distributors
Duration
8 to 12 hours (may span 2 days for civil trenching)
Outage Window
6 to 8 hours during utility isolation
Permit & Inspection
ESA Certificate of Acceptance
Includes Licensed Electrical Contractor labour, materials, ESA permit, and local utility coordination.
Request Written EstimateService Overview & Technical Context
A true capacity upgrade often extends beyond the interior breaker panel to the external service entrance infrastructure. If your property currently receives electricity via a 100A-rated overhead mast or an undersized underground lateral cable, upgrading to 200A or 400A requires a "heavy-up." This involves installing a new 200A-rated exterior meter base, new heavy-gauge service entrance conductors (2/0 copper or 4/0 aluminum), a taller heavy-duty overhead mast with guy-wire bracing or new underground trenching, and formal service demarcation sign-off with your local electric utility (such as Toronto Hydro, Alectra Utilities, Elexicon Energy, or Hydro One).
Applicable Property Types
- Older GTA homes with low overhead clearance over driveways
- Properties where the existing meter base is rated for only 100A or 125A
- Luxury infill new builds requiring 400-amp high-capacity services
- Properties transitioning from overhead to underground utility feeds
Standard Amperage Scope
- 200A Overhead Service
- 200A Underground Service
- 400A (320A Continuous) Split Service
Signs & Triggers for This Upgrade
Local electric utility notifies homeowner that service mast does not meet height clearance standards
Meter base shows rust, water penetration, or is an obsolete 100-amp round enclosure
Interior panel upgrade to 200A is blocked because the external service cables are undersized
Overhead wires sag dangerously across the street, sidewalk, or neighboring property
Building an addition or detached auxiliary garden suite requiring dual metering
Homeowner Benefits & Protections
Ontario Electrical Safety Code (OESC) Standards
| Component / Metric | Specification | OESC Reference |
|---|---|---|
| Meter Socket | 200A rated, 4-jaw, ringless or ring-type complying with local LDC meter specification | OESC Section 6 / LDC Specification Book |
| Mast Conduit | Rigid galvanized steel conduit (minimum 2-inch or 2.5-inch diameter) | OESC Rule 6-112 |
| Ground Clearance | Minimum clearance over driveways and pedestrian areas per OESC and LDC rules | OESC Rule 6-112 & Table 33 |
Execution Workflow: How It Works
Utility Service Layout Application
Submission of electrical service layout request to the local utility (Alectra, Toronto Hydro, etc.) for point of attachment approval.
ESA Notification & Staging
Filing ESA permit and staging 2-inch rigid steel conduit, meter base, conductors, and weatherhead materials.
Utility Service Disconnect
Utility line crew drops overhead service wires or opens transformer disconnect.
Mast & Meter Base Construction
Dismantling old mast, installing new heavy-gauge rigid mast with roof boot flashing, securing new meter base, and pulling conductors.
ESA Service Connection Authorization
ESA Inspector inspects point of attachment, meter base ground, and sends electronic Connection Authorization to utility.
Utility Line Reconnection
Utility crew re-hangs overhead service drops, crimps tension connectors, re-installs smart meter, and energizes the home.
Frequently Asked Questions About This Service
Other Panel & Service Solutions
Residential 100A to 200A Electrical Panel Upgrade
Upgrade your home’s electrical distribution system from an outdated 60A or 100A service to a 200A breaker panel in full compliance with the Ontario Electrical Safety Code (OESC).
Obsolete & Hazardous Electrical Panel Replacement
Replacement of obsolete fuse boxes, Federal Pacific Stab-Lok, Commander, and Sylvania panels that pose fire risks or are rejected by Ontario home insurance underwriters.
EV Charger Installation & Electrical Capacity Preparation
Dedicated 240V circuits for Level 2 EV charging, panel capacity calculations per OESC Section 86, and smart load-sharing solutions for homes with limited panel space.
Heat Pump Electrical Preparation & Panel Upgrades
Electrical service and panel upgrades to accommodate cold-climate air-source heat pumps, central air handlers, and 10kW-20kW auxiliary backup electric heat strips.
Request an Assessment for Heavy-Up Electrical Service & Meter Base Upgrade
Connect with Licensed Electrical Contractors across the Greater Toronto Area.
Request Your 200A Panel & Service Quotation
Compliant with Ontario Electrical Safety Code (OESC) & Local Utility Requirements.